Polyacrylamide Gel Electrophoresis (PAGE) Slab Electrophoresis Chamber AE-6200

  High resolution separation with simple operation. One entire surface of gel sandwich is in contact with buffer for rapid heat dissipation and uniform gel temperature. It affords relatively fast, high resolution separation, while minimizing the possibility of smiling effect, distortion or diffusion of bands, without the requirement for cooling. A gel is held simply with unique pressure platen, without the use of screws or clamps, while eliminating the possibility of slippage or leakage. This chamber is transparent, has no obstructions to visibility, and provides ease of access to sample wells and observation of separation.
Dual Slab Chamber/Dual Mini Slab Chamber AE-6290/6510

  Temperature-controlled PAGE of proteins or nucleic acids. Consists of slab gel cast, chamber and TempCon (heat exchanger). One or two gels are run. Both two surfaces of each gel sandwich are in contact with buffer for the most effective temperature control of gels. The chamber has buffer inlet and outlet ports to connect with TempCon. TempCon has a circulation pump to recirculate buffer. TempCon also are connected with a thermostatic circulator. Heat exchange between buffer and circulation fluid is made within TempCon. This system affords 5 to 60°C control of buffer. Two types of gel sizes: 138mm x 130mm(AE-6290) and 90mm x 80mm(AE-6510).
mini PAGE Chamber  AE-6530

  High resolution separation of protein and nucleic acid in 2 gels of compact 90 x 80 x 1mm format. Simplified routines for ensured reliable operation. Minimized smiling with efficient heat dissipation. Sideways current leak eliminated to avoid outward diffusion of bands. Leak of gel solution and leak of buffer eliminated. Unique design for easy but ensured setting of gels.
mini PAGE (pageRun) AE-6531

  Powered mini PAGE system. No need for a separate power supply unit any more. You only have to connect it to an electric source and run. High resolution separation of protein and nucleic acid in 2 gels of compact 90 x 80 x 1mm format. Simplified routines for ensured reliable operation. Minimized smiling with efficient heat dissipation. Sideways current leak eliminated to avoid outward diffusion of bands. Leak of gel solution and leak of buffer eliminated. Unique design for easy but ensured setting of gels. Offered in a convenient package, ready to cast and run 2 gels of 1 mm thickness and 12 wells.
Compact PAGE AE-7300

  Compact type PAGE provided with power supply.  Gel size(60mm x 60mm) and apparatus body are very compact. Buffer volume required is only 90mL, as a result, running cost can be saved. Electrophoresis time is only 30 minutes. In spite of compact size and low price, it establishes the same level of resolution separation as the former mini-gel electrophoresis system.
miniQuencer AE-6141

  18 x 20cm, moderate gel size provides necessary and sufficient migration distances to reconcile high resolution separation with high operation efficiency over larger and smaller gels. Gel sandwich is backed by built-in aluminum heat sink, which is backed by water jacket, built-in and removable. Circulating thermostatic water through the water jacket provides temperature regulation of gel, that is essential for SSCP or differential display of nucleic acids, as well as cooling of gel.
Precast Gel PAGEL Precast Mini Gels AE-6000 series

  Precast polyacrylamide gels with performed wells and a stacking gel, ready to run in the ATTO mini PAGE systems. The high quality gels with quality-consistent gel formation ensure high resolution  separation and high gel-to-gel reproducibility. The glass cassettes provide faster heat dissipation and more uniform temperature than plastic cassettes. Uniform, single concentration gels and linear gradient gels are offered. They have a life of about 6 months when stored at about 2 to 8C.
Tris-Glycine e-PAGEL Precast Gels AE-6000 series

  Precast polyacrylamide gels with performed wells, specifically designed for use with ATTO mini PAGE systems. The ready-to-run gels simplify and speed protein and nucleic acid electrophoresis procedures. The gels afford either SDS-PAGE in Tris-Glycine buffer system. Single concentration and gradient gels with 14 or 18 sample wells are offered. The gels keep for about 6 months under 2 to 10°C storage. 
PAGEL Compact AE-6000 series

  Precast polyacrylamide gels with performed wells, specifically designed forAE-7300 Compact PAGE. Gel size is compact such as 60(W)mm x 60mm(H). Even if compact gel size, it realize high resolution separation and high reproducibility.

Equidistant/

 2-Dimensional Electrophoresis

Disk Electrophoresis  SJ-1060DCII

  Tube gel electrophoresis system designed for PAGE or SDS-PAGE and isoelectric focusing of protein and nucleic acid under cooled conditions. It accommodates up to 12 glass tubes of 7 or 9 mm outer diameter and 100 to 150 mm length. Circular electrodes, equidistant from each tube, ensure uniform current to all gels. It accepts circulation of cooling water for temperature control. It affords the first dimension isoelectric focusing for 2-D electrophoresis, as well as native or denaturing PAGE. Offered in a convenient kit.
Rectan-Gel Electrophoresis AE-6050B

  Suitable for 2-dimentional electrophoresis. By adoption of rectangle gel, the gel handling after gel casting and electrophoresis is simplified and the subject of disk gel is solved. It excels in the adhesion nature to slab gel, and there are little outflow and diffusion of a sample. Because of uniform gel temperature control, it affords relatively fast, high resolution separation, while minimizing the possibility of smiling effect.
Agarose Electrophoresis Submerged Agarose Electrophoresis AE-6111

  Submerged, horizontal agarose gel electrophoresis is one of the primary tools for molecular biology, as an easy, economic and efficient technique for separation of nucleic acids as well as analysis of PCR-amplified fragments. UV transparent gel tray for ease of gel viewing. Comb teeth designed to provide sharp band. Buffer recirculation ports to afford recirculation or cooling of buffer to avoid interference in separation.
AE-6111F12 x 16cm gel with 26 or 13 wells per comb. 
Submerged Agarose Electrophoresis AE-6125 / 6133

  Sub merged, horizontal agarose gel electrophoresis is one of the primary tools for molecular biology, as an easy, economic and efficient technique for separation of nucleic acids as well as analysis of PCR-amplified fragments. UV transparent gel tray for ease of gel viewing. Comb teeth designed to provide sharp band. Buffer recirculation ports to afford recirculation or cooling of buffer to avoid interference in separation.
AE-6125/6133F15 x 20 or 25cm gel with 32 or 16 wells per comb/20 x 15 or 20cm with 42 or 21 wells per comb.
Submerged Agarose Electrophoresis AE-6135

  Sub merged, horizontal agarose gel electrophoresis is one of the primary tools for molecular biology, as an easy, economic and efficient technique for separation of nucleic acids as well as analysis of PCR-amplified fragments. UV transparent gel tray for ease of gel viewing. Comb teeth designed to provide sharp band. Buffer recirculation ports to afford recirculation or cooling of buffer to avoid interference in separation.
AE-6135F25 x 12cm gel with 54 or 27 wells per comb.
Buffer Circulator AE-6380

  The mini-pump for buffer solution circulation. Distortion of the electrophoresis band pattern by pH deviation of buffer solution or temperature variation is prevented by circulation of buffer solution. 
Blotting HorizBlot AE- 6677/6678

  Fast, efficient semi-dry blotting of protein and nucleic acids. Height-adjustable, stainless steel cathode, and contamination-free, platinum-plated titanium anode. Simultaneous blotting up to 6 gels are possible. Perfect contact of gel and membrane. High blotting efficiency is ensured by uniform electrical field realized by horizontal plate electrodes.
Size of electrode: 15 x 15cm (AE-6677), 20 x 20cm(AE-6678)
CompactBlot AE-7500

  Compact semi-dry blotting apparatus provided with power supply. Stainless steel cathode, and contamination-free, platinum-plated titanium anode. Small size, low cost, easy and high operability. Blotting performance is the same as that of conventional ones.
Power Supply powerStation 1000VC/1000XP AE-8450 / 8750

  Electrophoresis use power supply. Up to 1000V constant voltage, up to 500mA constant current, up to 1000-minute timed run and automatic crossover (in addition, AE-8750 offers 200 Wattage constant output),  10 sets of voltage-current-time conditions, programmed, stored and easy accessed. Safety-protective automatic output shutdown to prevent operations from electric hazard. 2.5Kg light compact design. Easy to operate control panel with large and bright 4-digit LED display to read either set or actual conditions.  Convenient output pause function for temporary interruption or resetting. Minimized electrical noise for other lab instruments. Power failure protection.
myPower 300/500 AE-8130 / 8150

  7cm wide, 14.8cm high and 21cm deep small compact and lightweight electrophoresis use power supply. AE-8130 myPower 300, providing 300V and 400mA constant output with automatic crossover, suits horizontal agarose electrophoresis, semi-dry blotting and PAGE with up to 50VA output. AE-8150 myPower 500, providing 500V and 200mA constant output with automatic crossover, suits PAGE, horizontal agarose electrophoresis, mini semi-dry blotting with up to 25VA output. Up to 999 minutes timed output with alarm buzzer. User-friendly simple and easy operation. 2-line, 3-digit meter allows reading either set or actual voltage, current and time, during output. Convenient, dual power outlet in parallel. Safety shutdown against short and open circuit.
constaPower 3000 AE-8800

  Power supply for electrophoresis in which the output of up to 3000V voltage is possible . Up to 3000V constant voltage, up to 300mA constant current, up to 300W constant output, up to 99999-minute timed run and automatic crossover. Safety design. As it offers wide range of voltage, current and wattage, it suits disk, mini-slab/slab PAGE, submerged agarose electrophoresis, SSCP,  IEF etc.
CrossPower 150 (NOT available for 220-230V) AE-8300

  Power supply equipped with "Crossover ability" and it has the large current specification in which the current output up to maximum 4A is possible. Output ranges are up to 150V and up to 2A, or up to 75V and up to 4A . Automatic crossover function to lessen heat interference to separation, damage to gel and danger to operator. Reliable output stabilized against variations in voltage, load and temperature. It suits for the cases needed large current with relatively low voltage, such as submerged agarose electrophoresis, semi-dry blotting  in large gel format and Tank blotting.
Gel Photography and Picture Analysis Printgraph AE-6914/6911

  Gel documentation system consisting of a high sensitivity monochrome CCD camera, a various functions camera controller and a shading cabinet. Real-time photography of a sample is possible. There are two types of camera controllers, the one has picture saving function to Floppy Disks, the other dose not have. The shading cabinet is chosen from four types (FX type: good at gel extraction and easy handling, CX type: provided with light inside, DX type: small and low price, stand type: used in darkroom ) according to the purpose of use, the kind of sample, and the size of gel and cabinet.
Densitograph
(#English version under development)
AE-6920 M/V

  System which photos and saves electrophoresis gel patterns, and performs quantification from a stained image using picture analysis software. It's constituted of  "Printgraph", a personal computer (Windows), and analysis software.
  • Molecule-weight-presumption from the position information of molecular weight markers by "Zone-densitometry" method is possible.
  • Concentration quantification from the acquired accumulated value by measuring the band is possible.
  • Plural spot quantification of 2-dimensional electrophoresis patterns is possible by the method of "Spot measurement".
  • Dot-blot patterns arranged regularly can be measured at a time  by the method of "Plate measurement".
Electrophoresis
Peripherals
Staining and Destaining

Automatic Gel Stainer

AE-6610

  Designed to minimize operator's load as well as to provide higher reproducibility with technical consistency, by automating staining routines. Operation programmable for staining with reverse stain or silver stain, for staining and destaining with dye stain or ethidium bromide, for staining of blot membranes, and various staining techniques. Up to 9 files to program and store your staining protocols. Up to 20 steps per file to program a series of procedures. 
Gel Staining Reagent Silver Stain kit AE-1350

  High sensitivity band detection reagent kit after gel electrophoresis of protein and nucleic acid. Easy handling and the dyeing processing time is 50 - 55 minutes. The reagent includes pure water and four kinds of liquids. One dyeing reagent kit can dye about 50 mini-gels.
Reverse Stain kit AE-1300

  High sensitivity and high speed band detection reagent kit after gel electrophoresis of protein. sensitivity of coloring is 10 times higher than conventional ones. Detection time is about 20 - 25 minutes. A reagent includes pure water and three kinds of liquids. One dyeing reagent kit can dye about 50 mini-gels.
Gel Dryer RapiDry AE-3750

  Dual-Heater Gel Dryer. It has a 45 x 38cm wide gel drying area, which accommodates 1 or 2 sequencing gels, up to 6 PAGE gels, or up to 12 mini PAGE gels to be dried simultaneously. Dual-heater (one in the lid and one in the base) affords rapid drying and ensures even heat distribution. It provides 40 to 80°C temperature adjustment. 3-speed initial-temperature-rise selectable for delicate gels.  Up to 540 minutes timer. Simple and easy operation. 
RapiDry mini AE-3711

  Gel drying area : 20 x 19cm. Dual-heater (one in the lid and one in the base) affords rapid drying and ensures even heat distribution. Compact, easy-to-operate design. Fluoroplastic-coated heat panel. Full protection against overheat. 40 to 80°C temperature adjustment. Up to 180 minutes timer.
GELMASTER Model-1426

  The vacuum pump for gel dryer. It's connected directly to a gel dryer with a connecting tube, and absorbs. It is not necessary to connect other traps such as a cooling trap. Easy handling, maintenance and space-saving because of compact design.
Electrophoresis Set / System Mini-slab Electrophoresis set AEP-801

  A basic set of mini slab polyacrylamide gel electrophoresis of protein and DNA. You can start your experiment immediately after getting this system with precast gel.

[Composition] mini PAGE Chamber / PAGEL precast mini gel / Power Station 1000VC

Wide submerged agarose EP* set AEP-850

  Agarose electrophoresis of maximum of 108 samples is possible for separation of DNA or the analysis of PCR-amplified fragments,

[Composition] Submerged Agarose Electrophoresis (AE-6135)  / Power Station 1000VC

*EP: ElectroPhoresis

Multi-42 submerged agarose EP set AEP-851

  Agarose electrophoresis using large gel with the width of 20cm and 21/42 samples for separation of DNA or the analysis of PCR-amplified fragments.

[Composition] Submerged Agarose Electrophoresis (AE-6133) / Power Station 1000VC

Multi-30 submerged agarose EP set AEP-852

  Agarose electrophoresis using long gel with the length of 20cm and 16/32 samples for RFLP

[Composition] Submerged Agarose Electrophoresis (AE-6125) / Power Station 1000VC

miniQuencer standard set AEP-860

  PAGE with the gel size of 18x20cm for SSCP or differential display or nucleic acids.

[Composition] miniQuemcer (AE-6141E)  and miniGeling (AE-6141M: gel casting apparatus) / constaPower 3000

Home ] Up ]