GENTAUR Contact Gentaur

Up

GENTAUR Survey

GENTAUR Belgium BVBA BE0473327336
Voortstraat 49, 1910 Kampenhout BELGIUM
Tel 0032 16 58 90 45
Fax 0032 16 50 90 45
info@gentaur.com

GENTAUR Ltd. GB111298832
Howard Frank Turnberry House
1404-1410 High Road
Whetstone London N20 9BH
Tel 020 3393 8531 Fax 020 8445 9411
uk@gentaur.com
Natwest bank Whetstone
Account no. 82577846 sort code 602336

GENTAUR France SARL FR63484237888
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50
Fax 01 43 25 01 60
RCS Paris B 484 237 888
SIRET 48423788800017
RIB 30004 00187 00010092253 10
BNP PARIBAS PARIS PL MAUBERT BIC BNPAFRPPPRG
IBAN FR76 3000 4001 8700 0100 9225 310
france@gentaur.com

GENTAUR GmbH
DE815175831
Marienbongard 20
52062 Aachen Deutschland
Tel tech support 0241 56 00 99 68  Frau Karolina Eland
de@gentaur.com
or  Tel 0241 95 78 94 78 Mr Tryan Ilkov
Tel logistics 0241 40 08 90 86 Annick Verdeyen
Fax 0241 55  91 05 36
Bankleitzahl 39050000
IBAN DE8839050000107569353
Handelsregister Aachen HR B 16058
Steuernummer 201/5961/3925
de@gentaur.com

GENTAUR Nederland BV NL850396268B01
Kuiper 1
5521 DG Eersel Nederland
KVK nummer 52327027
Tel:  0208-080893  Fax: 0497-517897
nl@gentaur.com
IBAN: NL04 RABO 0156 9854 62   SWIFT RABONL2U

GENTAUR Poland Sp. z o.o. PL2040002710
Ulica Ogarna 15/19B m2
80-826 GDANSK Poland
TEL Gdansk 058 710 33 44 FAX  058 710 33 48              
(TEL production Warsaw 0223 98 82 21)
poland@gentaur.com

GENTAUR U.S.A
Genprice Inc, Logistics
547, Yurok Circle
San Jose, CA 95123
Phone: (408) 472-2934
Fax: (408) 416-3994
before 9 a.m. Phone (718)513-2983
sales@genprice.com

Genprice Inc, Invoices and accounting
6017 Snell Ave
San Jose, CA 95123

GENTAUR Italy
20135 Milano
Tel 02 36 00 65 93 Fax 02 36 00 65 94
italia@gentaur.com

GENTAUR Spain
tel:0911876558
spain@gentaur.com

GENTAUR BULGARIA BG201358931
53, Graf Ignatiev Str. ent.V, fl. 2
Sofia 1000
Tel 0035929830070
Fax 0035929830072
sofia@gentaur.com

ГЕНТАУЪР БЪЛГАРИЯ
ID # 201 358 931 /BULSTAT
София 1000, ул. "Граф Игнатиев" 53 вх. В, ет. 2
Tel 0035929830070 Fax 0035929830072
e-mail: Sofia@gentaur.com
IBAN: BG11FINV91501014771636
BIC: FINVBGSF

Other countries
Österreich +43720880899
Canada Montreal +15149077481
Ceská republika Praha +420246019719
Danmark +4569918806
Finland Helsset +358942419041
Magyarország Budapest +3619980547
Ireland Dublin+35316526556
Luxembourg+35220880274
Norge Oslo+4721031366
Sverige Stockholm+46852503438
Schweiz Züri+41435006251
US New York+17185132983

 

N,N-Bis(2-hydroxyethyl)-2-aminoethanesulfonic acid

[10191-18-1]


C6H15NO5S = 213.25

Unit

 

 

 

Product code

25 g
100 g
1 kg

 

 

 

 

Appearance: white crystalline powder
Assay: > 99.0 % (Tit.)
Loss on drying : < 0.3 %
Absorbance : 0.025 (300nm)
Sulfate ash: < 0.1 %
Heavy metals: < 0.0005 %
Fe content: < 0.0005 %
 

Material Safety Data Sheet (MSDS)

This product is a chemical substance and is intended to be used by persons having chemical knowledge and skill, at their own discretion and risk.
 

IDENTITY : BES

Section I. 
 Manufacturer's Name :	GENTAUR LABORATORIES 
 
Section II.-Identity Information 
 Chemical Name : N,N-Bis(2-hydroxyethyl)-2-aminoethanesulfonic acid 
 CAS Registry Number : 			10191-18-1 
 OSHA PEL : 				Not available 
 ACGIH TLV : 				Not available
                                                      
Section III.Physical/ChemicalCharacteristics 
 Melting Point : 			150 - 157 C(dec.) 
 Boiling Point : 			Not applicable 
 Specific Gravity(Water=1) : 		Not applicable 
 Vaper Pressure :			Not applicable 
 Vaper Density(Air=1) : 		Not applicable 
 Evaporation Rate(Butyl Acetate=1) : 	Not applicable 
 Solubility in Water : 			Soluble 
 Appearance and Odor : 			White crystalline powder
                               
Section IV.-Fire and Explosion Hazard Data                              
 Flash Point(Method Used) : 		Not available 
 Flammable Limits : 			Not available 
 Extinguishing Media : Carbon dioxide, dry chemical powder, foam, water. 
 Special Fire Fighting Procedures :  
       Wear protective clothing, respirator, chemical safety goggles, 
       rubber boots and heavy rubber gloves. 
 Unusual Fire and Explosion Hazards :  
       Fire may produce irritating or poisonous gases. 

Section V.-Reactivity Data Stability : Stable Conditions to Avoid : Heat, sunlight, high temperature. Incompatibility(Materials to Avoid) : Strong oxidizing agents, strong acids, Hazardous Decomposition or Byproducts : When decomposed it may emit toxic fumes of carbon monoxide, carbon dioxide, nitrogen oxides and sulfur oxides. Hazardous Polymerization : Will Not Occur Conditions to Avoid : Not applicable

Section VI.-Health Hazard Data Route(s) of Entry : Inhalation ? Yes ; Skin ? Yes ; Ingestion ? Yes Health Hazards(Acute and Chronic) : May be harmful by inhalation,ingestion, or skin absorption. Causes eye and skin irritation. Material is irritating to mucous membranes and upper respiratory tract. Carcinogenicity : Not listed in RTECS. Signs and Symptoms of Exposure : Not available Medical Conditions Generally Aggravated by Exposure : Not available Emergency and First Aid Procedures : In case of contact with eyes, immediately flush eyes with copious amounts of water for at least 15 minutes. In case of contact, immediately wash skin with soap and copious amounts of water. Assure adequate flushing of the eyes by separating the eyelids with fingers. If inhaled, remove to fresh air. If not breathing, give artifical respiration. If breathing is difficult, give oxygen. If ingested, wash out mouth with water. Call a physician. Wash contaminated clothing before reuse.

Section VII.-Precautions for Safe Handling and Use Steps to be Taken in Case Material is Released or Spilled : Wear self-contained breathing apparatus, rubber boots and heavy rubber gloves. Avoid raising dust. Evacuate area. Ventilate area and wash spill site after material pickup is complete. Sweep up, place in a bag and hold for waste disposal. Waste Disposal Method : Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber. Precautions to be taken in Handling and Storing : Wear appropriate NIOSH/MSHA-approved respirator, chemical-safety goggles, chemical-resistant gloves, other protective clothing. Use only in a chemical fume hood. Mechanical exhaust required. Safety shower and eye bath. Faceshield. Do not breathe dust. Do not get in eyes, on skin,on clothing. Wash thoroughly after handling. Other Precautions : Keep tightly closed. Store in a cool and dry place.

Section VIII.-Control Measures Respiratory Protection(Specify Type) : Necessary. Ventilation, Local Exhaust : Chemical fume hood. Special : Mechanical(General) : Necessary Other : Protective Gloves : Chemical-resistant gloves. Eye Protection : Chemical-safety goggles. Other protective Clothing or Equipment : Necessary. Work/Hygienic Practices : Wash thoroughly after handling. Access to a safety shower and eye-wash. Do not permit eating, drinking or smoking near material.

 